§ 4-169. Minimum design and installation requirements.  


Latest version.
  • (a)

    No irrigation design or installation shall require the use of any component, including the water meter, in a way which exceeds the manufacturer's published performance limitations for the component.

    (b)

    Spacing.

    (1)

    The maximum spacing between emission devices must not exceed the manufacturer's published radius or spacing of the device(s). The radius or spacing is determined by referring to the manufacturer's published specifications for a specific emission device at a specific operating pressure.

    (2)

    New irrigation systems shall not utilize above-ground spray emission devices in landscapes that are less than sixty (60) inches not including the impervious surfaces in either length or width and which contain impervious pedestrian or vehicular traffic surfaces along two (2) or more perimeters. Qualifying areas less than sixty (60) inches may be irrigated utilizing subsurface or drip irrigation, pressure compensating tubing, or be designed without irrigation. If pop-up sprays or rotary sprinkler heads are used in a new irrigation system, the sprinkler heads must direct flow away from any adjacent surface and shall not be installed closer than four (4) inches from a hardscape, such as, but not limited to, a building foundation, fence, concrete, asphalt, pavers, or stones set with mortar.

    (3)

    Narrow paved walkways, jogging paths, golf cart paths or other small areas located in cemeteries, parks, golf courses or other public areas may be exempted from this requirement if the runoff drains into a landscaped area.

    (c)

    Water pressure. Emission devices must be installed to operate at the minimum and not above the maximum sprinkler head pressure as published by the manufacturer for the nozzle and head spacing that is used. Methods to achieve the water pressure requirements include, but are not limited to, flow control valves, a pressure regulator, or pressure compensating spray heads.

    (d)

    Piping. Piping in irrigation systems must be designed and installed so that the flow of water in the pipe will not exceed a velocity of five (5) feet per second for polyvinyl chloride (PVC) pipe.

    (e)

    Irrigation zones. Irrigation systems shall have separate zones based on plant material type, microclimate factors, topographic features, soil conditions, and hydrological requirements. All non-turf landscape areas shall be designed with subsurface irrigation, drip irrigation, and/or pressure compensating tubing.

    (f)

    Matched precipitation rate. Zones must be designed and installed so that all of the emission devices in that zone irrigate at the same precipitation rate.

    (g)

    Irrigation systems shall not spray water over surfaces made of concrete, asphalt, brick, wood, stones set with mortar, or any other impervious material, such as, but not limited to, walls, fences, sidewalks, and streets.

    (h)

    Master valve. A flow control master valve shall be installed on the discharge side of the backflow prevention device on all new installations.

    (i)

    Pop-up heads. Pop-up heads shall be installed at grade level and operated to extend above all landscape turfgrass.

    (j)

    PVC pipe primer solvent. All new irrigation systems that are installed using PVC pipe and fittings shall be primed with a colored primer prior to applying the PVC cement in accordance with the plumbing chapter or the construction chapter of the City Code.

    (k)

    Operational rain or moisture and freeze shut-off devices or other technology. All new automatically controlled irrigation systems must include operational sensors or other technology designed to inhibit or interrupt operation of the irrigation system during periods of freezing weather and moisture or rainfall. Freeze and rain or moisture shut-off technology must be installed according to the manufacturer's published recommendations. Rain or moisture and freeze shut-off devices installed must be of a type established and published by the regulatory authority.

    (l)

    Isolation valve. All new irrigation systems must include an isolation valve between the water meter and the backflow prevention device.

    (m)

    Depth coverage of piping. Piping in all irrigation systems must be installed according to the manufacturer's published specifications for depth coverage of piping.

    (1)

    If the manufacturer has not published specifications for depth coverage of piping, the piping must be installed to provide minimum depth coverage of six (6) inches of select backfill, between the top of the pipe and the natural grade of the topsoil. All portions of the irrigation system that fail to meet this standard must be noted on the irrigation plan. If the area being irrigated has rock at a depth of six (6) inches or less, select backfill may be mounded over the pipe. Mounding must be noted on the irrigation plan and discussed with the irrigation system owner or owner's representative to address any safety issues.

    (2)

    Utility, manmade structure or roots create an unavoidable obstacle, which makes the six-inch depth coverage requirement impractical, the piping shall be installed to provide a minimum of two (2) inches of select backfill between the top of the pipe and the natural grade of the topsoil.

    (3)

    All trenches and holes created during installation of an irrigation system must be backfilled and compacted to the original grade.

    (n)

    Wiring irrigation systems.

    (1)

    Underground electrical wiring used to connect an automatic controller to any electrical component of the irrigation system must be listed by Underwriters Laboratories as acceptable for burial underground.

    (2)

    Electrical wiring that connects any electrical components of an irrigation system must be sized according to the manufacturer's recommendation.

    (3)

    Electrical wire splices which may be exposed to moisture must be waterproof as certified by the wire splice manufacturer.

    (4)

    Underground electrical wiring that connects an automatic controller to any electrical component of the irrigation system must be buried with a minimum of six (6) inches of select backfill.

    (o)

    Water contained within the piping of an irrigation system is deemed to be non-potable. No drinking or domestic water usage, such as, but not limited to, filling swimming pools or decorative fountains, shall be connected to an irrigation system. If a hose bib (an outdoor water faucet that has hose threads on the spout) is connected to an irrigation system for the purpose of providing supplemental water to an area, the hose bib must be installed using a quick coupler key on a quick coupler installed in a covered purple valve box and the hose bib and any hoses connected to the bib must be labeled "non potable, not safe for drinking." An isolation valve must be installed upstream of a quick coupler connecting a hose bib to an irrigation system.

    (p)

    A licensed irrigator or a licensed irrigation technician shall be on-site at all times while the landscape irrigation system is being installed. When an irrigator is not onsite, the irrigator shall be responsible for ensuring that a licensed irrigation technician is on-site to supervise the installation of the irrigation system.

(Ord. No. 2010-48, § 1(Exh. A), 11-2-10)